Design checks for a reinforced concrete cantilever retaining wall on a spread footing: external stability to the French standard NF P 94-281 (Eurocode 7), reinforcement to EN 1992-1-1, seismic check to EN 1998-5.
The sheet applies the French national annexes: its interface and the PDF calculation note are in French.
How to use
- Geometry: stem height and thicknesses, toe, heel and footing thickness; the wall cross-section is drawn as you type.
- Soils: backfill (unit weight, friction angle, slope and height of the sloping ground), foundation soil (friction angle, cohesion, embedment, net ultimate bearing pressure q′u from the ground investigation report) and groundwater, if any, upstream and downstream; optional soil in front of the toe (reduced passive resistance) and shear key under the footing.
- Loads: up to six surcharge cases on the backfill (uniform, strip, line or point load, variable or permanent), each with its own combinations; loads at the top of the stem.
- “Calculer” gives the verdict, the utilisation ratio of each criterion and suggestions; the PDF calculation note can be downloaded below the results.
Assumptions
- Earth pressure: virtual vertical back behind the heel with the soil wedge acting with the wall (NF P 94-281), Coulomb on the actual back of the stem, or Coulomb wedge on the actual ground profile; sloping ground accounted for through the height of the virtual back, the soil prism above the heel and the vertical component of the thrust; strip and line loads by Krey’s method, modified Boussinesq or the Coulomb wedge.
- External stability, Design Approach 2: SLS and ULS combinations of the French MUR program guide (table 1: factored weights and thrust, variable load × γQ on the heel or its thrust × 1.35 beyond the virtual back, γQ = 1.35 by default); eccentricity (1 − 2e/B ≥ 1/15 at ULS, 1/2 at SLS), sliding (on the inclined plane AB with a shear key), bearing capacity with the load inclination factor iδ; passive resistance in front of the toe neglected by default, reduced by kp as an option.
- Stem: bending at ULS, minimum reinforcement, crack control (direct calculation of wk or the rule of the French annex to EN 1992-2), shear without shear reinforcement, anchorage in the footing; footing designed under the linear soil reaction of each combination (heel and toe).
- Seismic: pseudo-static method of EN 1998-5 Annex E (Mononobe-Okabe), design friction angles, submerged soil and hydrodynamic water pressure; sliding, overturning and bearing capacity (Annex F); stem in bending and shear (γc = 1.30, γs = 1.00).
- Water: submerged unit weight below the water table, water pressure on the upstream and downstream virtual backs, uplift under the footing; wall without counterforts, calculation per metre of wall.
Example
Inverted T wall, 4.60 m high, horizontal backfill with a 10 kPa surcharge, foundation soil with φ′ = 32°, seismic zone 2; calculation per metre of wall.
✔ Wall verified
Maximum utilisation ratio: 0.98 — governing criterion: stem: crack width wk
- Sliding
- 0.54
- Bearing
- 0.44
- As stem
- 9.42 cm²/m
- Earth thrust
- 63 kN/m
Ample external stability, footing fully in compression. Cracking of the stem sets its bars: 9.42 cm²/m (HA16 every 21 cm) instead of 7.17 cm²/m at ULS. Seismic: ratio 0.94 at most (bearing, upward vertical acceleration).
Load this example into the sheet Calculation note of the example (PDF, 6 pages, in French)
Formulas, limits and references
Ka = tan²(45° − φ′/2); Pa = 0.5·γ·Ka·H² + q·Ka·H
Bearing: Vd − R0 ≤ Rv;d (NF P 94-261)
Limits
- Inverted T cantilever wall on a shallow footing, without counterforts; optional shear key, soil in front of the toe and passive resistance; granular backfill, slope and water table possible.
- q′u is an input from the geotechnical study; no overall stability, settlement or liquefaction.
- Replaces neither the geotechnical study nor detailing (drainage, joints).
References: NF P 94-281 and NF P 94-261; EN 1997-1 (design approach 2); EN 1992-1-1; EN 1998-5 (Annexes E and F); Cerema guide “Eurocode 7: application to walls” (2017); MUR program guide (Sétra).
Check: example checked by hand (Ka, thrusts, weights, sliding); soil in front of the toe, passive resistance, shear key, stem under seismic action and MUR guide factors compared with 97 reference values.
Frequently asked questions
Why a virtual back behind the heel?
The soil above the heel moves with the wall: earth pressure acts on a vertical plane behind the heel, and the weight of that soil stabilises the wall (NF P 94-281). Coulomb on the back of the stem is also available.
Where does q′u come from?
From the geotechnical study (pressuremeter or penetrometer tests, NF P 94-261). It is a net pressure: the check is on Vd − R0, R0 being the weight of soil at the level of the footing base.
Is a seismic check required?
It depends on the seismic zone and the importance category: none in zone 1; beyond, pseudo-static method of EN 1998-5 (kh = 0.086 in the example).
See also
Sheet for preliminary design and routine checks, provided for guidance only: it replaces neither the ground investigation report nor a calculation note prepared by an engineer. Found an issue or have a suggestion? Write to us.